Honeywell EMM3UK/U Mini Zone Warm Air and Air Conditioning Zone Control Panel Kit

Item SKU - EMM3UK/U by Honeywell
EDP - 710751


Please Login for Pricing

Product Description

Old Number EMM3UK

Includes: 1 - Emm3U Zone control panel, 1 - AT140 Transformer, and 1 - C7735A Discharge air temperature sensor

Compatible with single stage, multi stage, conventional or heat pump applications - Works with virtually any Honeywell 4 wire

single stage or multi stage heat pump thermostat - System and zone LED's indicate system status - Automatic zone changeover

with 20 minute changeover timer - Individual zone fan control - Thermal circuit breaker protects panel and transformer from

damage if miss wired - Purge timer protects equipment between calls for heating and cooling - Uses spring open/power closed,

spring closed/power open, and power open/power closed dampers - Interfaces with single or dual transformer equipment.

Documentation

Specifications

These specifications are subject to change by the manufacturer, and are only approximate. For precise specifications, please call our inside sales department at 860-221-SALE (860-221-7253).

Zones
3
Stages of Heat
2
Stages of Cool
2
Includes Transformer and Air Sensor
No
Zone Damper Compatibility
4 Wire
RedLink Compatible
No
Incoming Voltage
115
Output Voltage
24
Expandable
No
Approximate Weight (pounds)
4.20

Honeywell EMM3UK/U Mini Zone Warm Air and Air Conditioning Zone Control Panel Kit

Item SKU - EMM3UK/U by Honeywell (EDP 710751)

Stock / Price Information

Please Login for Pricing

Product Description

Old Number EMM3UK

Includes: 1 - Emm3U Zone control panel, 1 - AT140 Transformer, and 1 - C7735A Discharge air temperature sensor

Compatible with single stage, multi stage, conventional or heat pump applications - Works with virtually any Honeywell 4 wire

single stage or multi stage heat pump thermostat - System and zone LED's indicate system status - Automatic zone changeover

with 20 minute changeover timer - Individual zone fan control - Thermal circuit breaker protects panel and transformer from

damage if miss wired - Purge timer protects equipment between calls for heating and cooling - Uses spring open/power closed,

spring closed/power open, and power open/power closed dampers - Interfaces with single or dual transformer equipment.

Documentation

Specifications

These specifications are subject to change by the manufacturer, and are only approximate. For precise specifications, please call our inside sales department at 860-221-SALE (860-221-7253).

Zones
3
Stages of Heat
2
Stages of Cool
2
Includes Transformer and Air Sensor
No
Zone Damper Compatibility
4 Wire
RedLink Compatible
No
Incoming Voltage
115
Output Voltage
24
Expandable
No
Approximate Weight (pounds)
4.20